District/Families
|
Front
(Ft.)
|
Rear
(Ft.)
|
Between Buildings
(Ft.)
|
Interior Side
(Ft.)
|
Side Street
(Ft.)
|
RU-1:
One
|
25 for subdivisions platted on or before March 8, 2002; for subdivisions platted after
March 8, 2002, 15 for 50% of the lineal footage of the width of the house and 25 for
balance; except 20 for attached garages
|
25 for subdivisions platted on or before March 8, 2002; for subdivisions platted after
March 8, 2002, 15 for 50% of the lineal footage of the width of the house and 25 for
balance
|
—
|
10% lot width
min.—5′
max.—7½′
|
15
|
Acc. bldg.
|
75
|
5
|
10
|
same as RU-1 res.
|
equal to front setback requirements for principal structure on key lot, plus 5′; 20′
where there is no key lot.
|
Canopy carport
|
5
|
5
|
—
|
2
|
5
|
RU-1M(a):
|
25 for subdivisions platted on or before March 8, 2002; for subdivisions platted after
March 8, 2002, 15 for 50% of the lineal footage of the width of the house and 25 for
balance; except 20 for attached garages
|
25 for subdivisions platted on or before March 8, 2002; for subdivisions platted after
March 8, 2002, 15 for 50% of the lineal footage of the width of the house and 25 for
balance
|
—
|
5
|
10
|
Acc. bldg.
|
75
|
5
|
10
|
5
|
15
|
Canopy carport
|
5
|
5
|
—
|
2
|
5
|
RU-1M(b):
|
25 for subdivisions platted on or before March 8, 2002; for subdivisions platted after
March 8, 2002, 15 for 50% of the lineal footage of the width of the house and 25 for
balance; except 20 for attached garages
|
25 for subdivisions platted on or before March 8, 2002; for subdivisions platted after
March 8, 2002, 15 for 50% of the lineal footage of the width of the house and 25 for
balance
|
—
|
6
|
10
|
Acc. bldg.
|
75
|
5
|
10
|
6
|
15
|
Canopy carport
|
5
|
5
|
—
|
2
|
5
|
RU-2:
One
|
|
|
—same as RU-1 res.—
|
Two singles:
Front
|
|
|
—same as RU-1 res.—
|
Rear
|
|
|
—same as RU-1 acc. bldg.—
|
Duplex
|
|
|
—same as RU-1 res.—
|
Acc. bldg.
|
|
|
—same as RU-1 acc. bldg.—
|
Canopy carport
|
5
|
5
|
—
|
2
|
5
|
RU-3:
One
|
|
|
—same as RU-1 res.—
|
Two singles
|
|
|
—same as two singles in RU-2—
|
Duplex
|
|
|
—same as RU-1 res.—
|
Three or four
|
25
|
25
|
—
|
15
|
25
|
Acc. bldg.
|
75
|
5
|
10
|
7½
|
30
|
Canopy carport
|
5
|
5
|
—
|
2
|
5
|
RU-3B:
One
|
|
|
—same as RU-1 res.—
|
Two singles
|
|
|
—same as two singles in RU-2—
|
Duplex
|
|
|
—same as RU-1 res.—
|
Three or four
|
|
|
—same as 3 or 4 unit in RU-3—
|
Bungalow court
|
|
|
—see RU-3B—
|
Acc. bldg., 1 to 4 units
|
75
|
5
|
10
|
7½
|
30
|
RU-4 & RU-4A:
One
|
|
|
—same as RU-1 res.—
|
Two singles
|
|
|
—same as two singles in RU-2—
|
Duplex
|
|
|
—same as RU-1 res.—
|
Three or four
|
|
|
—same as 3 or 4 units in RU-3—
|
Five or more
|
|
|
—see RU-4 and RU-4A—
|
Acc. bldg.
|
75
|
5
|
10
|
7½
|
30
|
EU-M:
One
|
25
|
25
|
—
|
15
|
25
|
Acc. bldg.
|
75
|
7½
|
10
|
20
|
30
|
Canopy carport
|
5
|
5
|
—
|
2
|
5
|
EU-S:
One
|
35
|
25
|
—
|
15
|
25
|
Acc. bldg.
|
75
|
7½
|
10
|
20
|
30
|
Canopy carport
|
13
|
5
|
—
|
2
|
5
|
EU-1:
One
|
50
|
25
|
—
|
15
|
25
|
Acc. bldg.
|
|
|
—same as EU-M accessory buildings—
|
Canopy carport
|
28
|
5
|
—
|
2
|
5
|
EU-1C
|
|
|
—same as EU-1—
|
EU-2
|
|
|
—same as EU-1—principal building and entrance lodge same as principal building in
EU-1—all other buildings not closer than 85′ to the highway right-of-way
|
Canopy carport
|
28
|
5
|
—
|
2
|
5
|
AU
|
|
|